MADIT-CRT Medical Journal Article Reprint Disclosure


Boston Scientific’s CRT-D indication is limited to a sub-population of MADIT-CRT patients with left bundle branch block morphology. It is important to note that left bundle branch block (LBBB) was not an inclusion parameter for the MADIT-CRT trial. However, a significant interaction between treatment and bundle branch block morphology was detected. Further analyses revealed that LBBB is an objective discriminator of patient benefit from CRT-D (primary endpoint) regardless of other baseline characteristics. For the complete clinical trial information used to support BSC’s device indications, go to bostonscientific.com/ifu.  

CRT-D Systems from Boston Scientific CRM

The following statements are based on clinical information consistent with current device labeling and are not based on published MADIT-CRT Trial Results. For the current CRT-D labeling, go to www.bostonscientific.com/ifu.

 

Indications and Usage

These Boston Scientific Cardiac Resynchronization Therapy Defibrillators (CRT-Ds) are indicated for patients with heart failure who receive stable optimal pharmacologic therapy (OPT) for heart failure and who meet any one of the following classifications:

  • Moderate to severe heart failure (NYHA Class III-IV) with EF ≤ 35% and QRS duration ≥ 120 ms
  • Left bundle branch block (LBBB) with QRS ≥ 130 ms, EF ≤ 30%, and mild (NYHA Class II) ischemic or nonischemic heart failure or asymptomatic (NYHA Class I) ischemic heart failure

 

Contraindications

There are no contraindications for this device.

 

Warnings

Read the product labeling thoroughly before implanting the pulse generator to avoid damage to the system. Such damage can result in patient injury or death. For single patient use only. Do not reuse, reprocess, or resterilize. Reuse, reprocessing, or resterilization may compromise the structural integrity of the device and/or lead to device failure which, in turn, may result in patient injury, illness, or death. Reuse, reprocessing, or resterilization may also create a risk of contamination of the device and/or cause patient infection or cross-infection, including, but not limited to, the transmission of infectious disease(s) from one patient to another. Contamination of the device may lead to injury, illness, or death of the patient. Program the pulse generator Tachy Mode to Off during implant, explant or postmortem procedures to avoid inadvertent high voltage shocks. Always have sterile external and internal defibrillator protection available during implant. If not terminated in a timely fashion, an induced tachyarrhythmia can result in the patient's death. Ensure that an external defibrillator and medical personnel skilled in CPR are present during post-implant device testing should the patient require external rescue. Advise patients to seek medical guidance before entering environments that could adversely affect the operation of the active implantable medical device, including areas protected by a warning notice that prevents entry by patients who have a pulse generator. Do not expose a patient to MRI device scanning. Strong magnetic fields may damage the device and cause injury to the patient. Do not subject a patient with an implanted pulse generator to diathermy since diathermy may cause fibrillation, burning of the myocardium, and irreversible damage to the pulse generator because of induced currents. Do not use atrial-tracking modes in patients with chronic refractory atrial tachyarrhythmias. Tracking of atrial arrhythmias could result in VT or VF. Do not use atrial-only modes in patients with heart failure because such modes do not provide CRT. LV lead dislodgment to a position near the atria can result in atrial oversensing and LV pacing inhibition. Physicians should use medical discretion when implanting this device in patients who present with slow VT. Programming therapy for slow monomorphic VT may preclude CRT delivery at faster rates if these rates are in the tachyarrhythmia zones. Do not kink leads. Kinking leads may cause additional stress on the leads, possibly resulting in lead fracture. Do not use defibrillation patch leads with the CRT-D system, or injury to the patient may occur. Do not use this pulse generator with another pulse generator. This combination could cause pulse generator interaction resulting in patient injury or lack of therapy delivery. For specific models, when using a subpectoral implantation, place the pulse generator with the serial number facing away from the ribs. Implanting the pulse generator subpectorally with the serial number facing the ribs may cause repetitive mechanical stress to a specific area of the titanium case, potentially leading to a component failure and device malfunction.

 

Precautions

For information on precautions, refer to the following sections of the product labeling: clinical considerations; sterilization, storage and handling; implant and device programming; follow-up testing; explant and disposal; environmental and medical therapy hazards; hospital and medical environments; home and occupational environments. Advise patients to avoid sources of electromagnetic interference (EMI) because EMI may cause the pulse generator to deliver inappropriate therapy or inhibit appropriate therapy.

 

Potential Adverse Events

Potential adverse events from implantation of the CRT-D system include, but are not limited to, the following: allergic/physical/physiologic reaction, death, erosion/migration, fibrillation or other arrhythmias, lead or accessory breakage (fracture/insulation/lead tip), hematoma/seroma, inappropriate or inability to provide therapy (shocks/pacing/sensing), infection, procedure related, and component failure. Patients may develop psychological intolerance to a pulse generator system and may experience fear of shocking, fear of device failure, or imagined shocking. In rare cases severe complications or device failures can occur.

 

Refer to the product labeling for specific indications, contraindications, warnings/ precautions and adverse events. Rx only.
(Rev. N)

 


By selecting the link below, you are indicating you have read and understand the above disclosure.


View & Print the NEJM Article: Cardiac-Resynchronization Therapy for the Prevention of Heart-Failure Events »

[The above link accesses an executable file. Choose Run or Save to access the article. If you save it, be sure to add an .exe file extension to the end of the file name prior to saving to your system or it will not work properly. You may view it as much as you would like, but may only print twice]

To save your ePrint – Please follow these steps:
Step 1. To download the file, click on the "Download File" link provided above
Step 2. To save the file to your desktop, click the “Save” button
Step 3. Locate the file on your desktop and double click to open
*** IMPORTANT NOTICE ***
This Mobile ePrint is ONLY supported on the PC platform. For any ePrint support questions, or if you are a Mac user please send an email to: requestinfo@tsp.sheridan.com.

 


 

^ Back to top

 

 

 

 

 

 

 

CRM6-1612-0909